Toto RENESSE Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3) Installation of the Valve
(Stem Adapter, Limiter Collar and Temperature Limiter)
Trim installation should not be begun until the
followings are confirmed:
1) Checking the water flow
2) Checking the filters
Install the stem adapter into the valve as shown.
Confirm that distance between Finished Wall
and top of Limiter Collar is between
and 1-3/8" (35 mm).
If not, Spacer should be removed as follow:
How to remove the Spacer
1) Take out the Stem Adjuster, unscrew the
Limiter Collar and pull out the Temperature
Limiter.
2) Then, Remove the Spacer as shown.
3) Attach the Temperature Limiter, making
sure that Circle Mark on the Limiter align
with middle top point of the valve.
4) Then, tighten the Limiter Collar and
reattached the Stem Adjuster.
Caution
1) Be sure to reattach the Temperature
Limiter.
2) Tighten the Limiter Collar firmly.
3) Make sure the Circle Mark points
upward.
7
Caution
1" (25 mm)
Stem Adjuster
Limiter Collar
Spacer
Loosen.
Limiter Collar
Stem Adjuster
Tighten.
Limiter Collar
Stem Adjuster
Thermostatic
Mixing valve
1" (25 mm) MIN
1-3/8" (35 mm) MAX
middle top point
Temperature
Limiter
Right above
Circle Mark
Temperature
Limiter

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Renesse tskt

Tabla de contenido