Please see following instruction on how to adjust the output
temperature if it is shown incorrectly in the previous step.
1) Keep turning the temperature control handle to the
Hot side while reading a temperature indicator.
Stop turning it when the indicator reads 104°F.
2) Let the water run while removing the
temperature control handle by taking off the cap
and unscrewing the screw.
3) Make sure that "104" on the handle is in
line with Mark on the coverplate and
reattach the temperature control handle.
4) Put the screw and cap on and, again, confirm the
output water temperature, making sure that it is 104°F
in the middle.

Calibrating the valve

calibrating the valve will be required if following the above
instructions do not result in correct remperature reading.
1) Shut of the HOT and Cold water supply
at the service stops.
2) Remove the Stem Adjuster, Limiter Collar
and temperature limiter.
3) Check to make sure that Circle Mark on
the temperature limiter align with middle
top point of the valve.
4) Reinstall the limiter and collar and turn on t
he water supply.
5) Turn the water on and let it run for about
1 minute. Place a thermometer in the water
stream while truning the handle to the HOT
side. Stop when it reads
6)Let the water run at
temperature and then install the handle and cap.
NNOTE: If the valve turned accidently, repeat the calibration procedure.
9
104°F (40°C).
104°F (40°C) water
Mark
"104"
Temperature
Control Handle
Screw
Cap
Spacer
Loosen.
Limiter Collar
Stem Adjuster
Tighten.
Temperature
Limiter
Limiter Collar
Stem Adjuster
middle top point
Temperature
Limiter
Right above
Circle Mark

Publicidad