Maintenance And Troubleshooting; Maintenance; Trouble-Shooting Guide; List Of Compatible 0-10V Dimmers - Acuity Brands AEDAN Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE AND TROUBLE SHOOTING

MAINTENANCE:

To clean, wipe OLED panels with a soft damp non-abrasive
cloth, and use gloves.
Rubbing alcohol may be used for cleaning purposes.
DO NOT use abrasive materials such as scouring pads or
powders, steel wool or abrasive paper.
DO NOT use any detergents, acids or chemical agents.
DO NOT attempt to remove OLED panels for cleaning purposes.

TROUBLE-SHOOTING GUIDE:

If this fixture fails to operate properly, use the guide below to
diagnose and correct the problem.
• Make sure that any of the OLED panels are not damaged.
• Verify that fixture is properly wired.
• Verify that fixture is correctly grounded.
• Verify that the line voltage at the fixture is correct (120V).
For further assistance or information, contact
Technical Support at (800) 748-5070.
14

LIST OF COMPATIBLE 0-10V DIMMERS:

(Dimming Range: 10%-100% Continuous Dimming)
Synergy Model Numbers:
ISD BC 120/277 XX
Lithonia Model Numbers:
ISD BC 120/277 WH M10
Lutron Model Numbers:
NTSTV-DV-XX
DVSTV-XX
DVSCSTV-XX
MS-Z101-XX
MS-Z101-V-XX
Leviton Model Numbers:
IP710-LFZ
AWSMG-7DW
AWSMT-7DW
NOTE: Consult Technical Support if you wish to use a
dimmer that is NOT on this list.

REPLACEMENT PART NUMBERS:

Part Number
Rectangular Front OLED Panel
Rectangular Rear OLED Panel