5B
Do not cut bus wires
• Measure exactly
1 3/8 in (35 mm).
• Lightly score inner
jacket around and
down as shown.
• Peel off jacket.
• Notch core.
• Peel bus wire from core.
• Score core between bus
wires at inner jacket.
• Bend and snap core.
• Peel core from bus wire.
• Remove any remaining core
material from bus wires.
4 | nVent.com
BTV, QTVR
1 3/8 in
(35 mm)
1/4 in
(5 mm)
Go to Step 6
5C
• Measure exactly
1 3/8 in (35 mm).
• Lightly score inner
jacket around and
down as shown.
• Peel off inner jacket.
• Unwind heating
element, cut and
remove as shown.
• Lightly score clear
jacket around and
down as shown.
• Remove insulation
from ends of bus
wires.
(13 mm)
VPL
Do not cut bus wires
1 3/8 in
(35 mm)
1/2 in
Go to Step 6

Publicidad

loading

Este manual también es adecuado para:

E-100-l1E-100-l2