Sears Kenmore 796.8138 Manual De Uso Y Cuidado página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

VENTING
THE DRYER
IMPORTANT!
CHECK YOUR EXHAUST
SYSTEM FOR PROBLEMS
The most common cause of dryer problems is poor
exhaust venting. Before installing your new dryer,
check the items listed below to make sure you get the
best possible performance.
This can save you time and
money by reducing
cycle times and increasing
energy
efficiency.
• DIRTY OR DAMAGED
EXHAUST DUCTS. Lint builds
up in exhaust ducts over time. This decreases the
airflow
and makes the dryer work harder. Visually
inspect your ducts from both ends and have them
cleaned if they have not been cleaned recently.
• WRONG
VENT MATERIAL. Check your vent to make
sure it is rigid or semi-rigid metal ducting. If your
venting is plastic or flexible
foil, have it replaced
before using the dryer.
• RESTRICTED OR DAMAGED VENT HOOD. Check
your vent hood outside. It must be clean and free of lint
buildup. Check the damper and make sure it opens fully
and easily.
• EXCESSIVELY LONG VENT. Measure the length of your
exhaust system and count the elbows. Use the chart
below to see if your duct is too long. If it is too long,
have the duct routed to another location that is within
the venting guidelines.
• DO NOT
USE PLASTIC
OR FOIL VENTING.
The
transition
duct
from
your
dryer
to the
wall
must be rigid
or semi-rigid
metal
ducting.
If your
old transition
duct is
plastic
or foil,
REPLACE
IT with
semi-rigid
metal
ducting.
Using the DUCT LENGTH CHART (below)
_1 Find your vent hood type in the chart below.
O
Select the row that matches the number of elbows in your dryer duct run.
Look to the right of the elbow number for the maximum duct length for your installation.
Longer duct length will result
in reduced drying performance,
longer dry times and increased energy consumption.
Extremely long ducts can even
shorten the life of the dryer.
DO NOT exceed the maximum
length for the vent hood type and number of elbows used.
(----I
1H
4"
(10.2
cm)
4"
(10.2
cm)
Only
for
Short-Run
Installations
1
2
3
4
0
55 feet (16.8 m)
47 feet (14.3 m)
36 feet(11.0
m)
28 feet (8.5 m)
55 feet (16.8 m)
21/2"
(6.35
cm )
1
2
3
4
47 feet (14.3 m)
41 feet (12.5 m)
30 feet (9.1 m)
22 feet (6.7 m)
NOTE: Deduct 6 ft. (1.8 m) for each additional
elbow. Using more than four 90 ° elbows is not recommended.
14

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kenmore 796.9138

Tabla de contenido