Self-Diagnostic Function - Sony TRINITRON KV-42DRC700 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/STEREO LED will automatically begin to fl ash. The number
of times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/STEREO LED fl ash indicators is listed in the
instruction manual for the user's knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/STEREO LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more
than one error, the LED will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a "0".
Diagnostic Item
Power does not turn on
+B Overcurrent (OCP)
(See Note 1)
+B Overvoltage (OVP)
Vertical Defl ection Stopped
White Balance Failure
(not balanced)
LOW B OCP/OVP
(overcurrent/overvoltage)
(See Note 3)
Horizontal Defl ection Stopped
Note 1: If a +B Overcurrent is detected, stoppage of the Vertical Defl ection is detected simultaneously. The symptom that is diagnosed fi rst by the microcontroller is displayed on screen.
Note 2: Refer to Screen (G2) Adjustment in Section 2-5. of this manual.
Note 3: If STANDBY/STEREO LED fl ashes six (6) times, unplug the unit and wait 10 seconds before performing the adjustment.
Display of STANDBY/STEREO LED Flash Count
Diagnostic items
Flash count
+B Overcurrent (OCP)
+B Overvoltage (OVP)
Vert. Deflection Stopped
White Balance Failure
Low B OCP/OVP
Horiz. Deflection Stopped
Lamp ON 0.3 sec.
Lamp OFF 0.3 sec.
Stopping the STANDBY/STEREO LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/STEREO LAMP from fl ashing.
Self-Diagnostic Screen Display
For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes out" that cannot be confi rmed, it is possible to bring up
past occurrences of failure on the screen for confi rmation.

SELF-DIAGNOSTIC FUNCTION

No. of times STANDBY/
STEREO lamp fl ashes
Display Result
Does not light
2 times
3 times
4 times
5 times
6 times
7 times
2 times
3 times
4 times
5 times
6 times
7 times
Lamp OFF 3 sec.
Probable Cause Location
• Power cord is not plugged in.
• Fuse is burned out F6001 (A Board).
2:0 or 2:1
• H.OUT (Q5030) is shorted (D Board).
• +B PWM (Q5003) is shorted (D Board).
• IC9001, IC9002, IC9003 is shorted (C Board).
3:0 or 3:1
• IC6505 is faulty (D Board).
4:0 or 4:1
• ± 15V is not supplied (D Board).
• IC5004 is faulty (D Board).
5:0 or 5:1
• Video OUT (IC9001-IC9003) is faulty (C Board). • No raster is generated.
• CRT drive (IC201) is faulty (A Board).
• G2 is improperly adjusted (See Note 2).
6:0 or 6:1
• +5 line is overloaded (A, B Boards).
• +5 line is shorted (A, B Boards).
• IC6007 is faulty (A Board).
7:0 or 7:1
— 7 —
KV-42DRC700
Self Diagnosis
Supported model
Detected Symptoms
• Power does not come on.
• No power is supplied to the TV.
• AC power supply is faulty.
• Power does not come on.
• Load on power line is shorted.
• Has entered standby mode.
• Has entered standby state after
horizontal raster.
• Vertical defl ection pulse is stopped.
• Power line is shorted or power
supply is stopped.
• CRT Cathode current detection
reference pulse output is small.
• No picture.
• No picture.
STANDBY/STEREO LED
* One fl ash count is not used for self-
diagnostic.