Cleaning the dust filter:
Please open the filter cover on the backside of the unit and carefully
remove the filter.
To remove dust from this filter, please use a vacuum cleaner or to tap it
out carefully.
If the filter is very dirty, wash it in water with neutral detergent, rinse well
with water and let it dry.
Carefully put the filter back into the unit and close the filter cover.
Storage
Please unplug the unit and bundle the power cord.
Please empty the water tank, wipe out the tank with a cloth and reinstall it.
Please clean the air filter as described above and then reinstall it in the unit.
For storage, place the unit in an upright position and avoid direct sunlight.

Troubleshooting

problem
The unit is not working
The dehumidification
performance is insufficient
Humidity does not drop
Loud noises during start-
up
Unpleasant smells during
start-up.
The start-up is
interrupted.
The clothes do not get
dry.
cause
Is the unit connected to the power
source?
Is the 'water tank full' indicator
lighting up (water tank is full or
incorrectly placed)?
Is the water tank installed correctly?
Are the air outlet slats open?
The unit is in defrost mode.
Is the air inlet or outlet blocked?
Is the air filter dirty?
Does the unit operate in the fan
mode?
Is the room temperature/humidity too
low high?
Is the room size too large?
Are all windows and doors in the
room closed?
Does the unit stand upright on the
stable surface?
The circulation of the refrigerant
inside may cause noise.
This is not a defect.
Is the room temperature higher than
the operating temperature?
Is the laundry too far away from the
unit?
Is the room temperature lower than
the operating temperature?
solution
Plug-in the unit.
Empty the water tank and install it correctly.
Please check the position of the water tank.
Please open the air outlet slats.
This is a normal process and helps to protect
internal parts. Once the process is complete,
the unit returns to normal operation.
Check the air inlet and outlet and remove
any obstructing objects
Clean the air filter as described in the
operating instructions
Please switch to dehumidification mode.
The unit should be operated at the air
temperature of 5°C - 32°C and a humidity of
10%-90%. The unit cannot dehumidify the air
optimally at ambient temperature and/or
humidity level below/above this.
Please observe the recommended room size
indicated on the packaging.
Please close all doors and windows if
necessary.
Place chek the position of the unit.
The noises disappear as soon as the
refrigerant circuit has stabilised.
Unpleasant smells during start up are normal
and will disappear after a short time. If the
surrounding objects are heavily soiled, e.g.
by cigarette smoke, this can also lead to
unpleasant smells from the air outlet.
The unit restarts automatically as soon as
the ambient temperature has dropped.
Please make sure the laundry is exposed to
the air flow.
The laundry dries more slowly when the
ambient temperature is low. Try drying your
laundry in another room.