3 TECHNICAL CHARACTERISTICS
TAB. 1
FORT 400
FORT 500
Power supply
Operating power
24 V
230 V~
supply
ONE 24V
Power consump-
70 W
280 W
tion
Rated input
3,0 A
1,2 A
Maximum thrust
350 N
450 N
Duty cycle
Intensive use
30%
Protection rating
Insulation
I I
class
Operating temp.
Max. gate weight
400 Kg
500 Kg
Rack module
Maximum speed
0.26 m/s
0.17 m/s
Motor weight
8,9 Kg
9,9 Kg
The values of use may vary for panelled gates insofar as affected by both the weight and movement in case of wind.
3.1 ACCESSORIES INCLUDED IN SUPPLY
MOTOR
4 INSTALLATION
BEFORE PERFORMING ANY TYPE OF OPERATION, CHECK THAT THE AUTOMATION IS DE-ENERGIZED.
4.1 PRELIMINARY CHECKS
For correct operation of the sliding automation, check that:
• All the accessories are properly rated.
• During manual operation, the gate does not abnormally sway or bend.
• There is a mechanical limit switch able to stop the gate in closure and in opening.
• The gate, if left free in any position, does not move on its own.
• Check for uniform friction along the entire gate stroke, both in closure and in opening.
4.2 LIMITS OF USE
Before installing the gearmotor, check that its technical specifications fall within the limits of use in chapter 3, "Technical characteristics". The
gate must not exceed the maximum weight allowed by the selected motor.
FORT 600
FORT 700
24 V
230 V~
ONE 24V
110 W
300 W
5,0 A
1,3 A
550 N
650 N
Intensive use
30%
I
I I
I
600 Kg
700 Kg
0.28 m/s
0.17 m/s
10,6 Kg
11.5 Kg
PLATE AC - 10 (1PZ)
(UNTIL EXHAUSTION)
FORT 800
FORT 1000
230 V~ 50 Hz
24 V
24 V
230 V~
ONE 24V
ONE 24V
150 W
320 W
150 W
5,6 A
1,4 A
6,2 A
750 N
Intensive use
30%
Intensive use
IP 44
I I
I
I I
from -20°C to + 50°C
800 Kg
M4
0.28 m/s
0.17 m/s
0.21 m/s
12 Kg
12 Kg
12 Kg
PLATE AC - 220 (1PC)
COMUNELLO ®Copyright 2020 - All rights reserved
FORT DUAL
FORT 1500
1000
230 V~
230 V~
230 V~
340 W
340 W
1,5 A
1,5 A
900 N
1400 N
30%
30%
I
I
1000 Kg
1000 Kg
1500 Kg
0.17 m/s
0.17 m/s
0.17 m/s
12,4 Kg
12,4 Kg
12,6 Kg
LIMIT SWITCH BRACKETS
(2 PCS - no.1 RH and no.1 LH)
460 W
2,0 A
30%
I