Comunello Automation FORT 400 Manual Del Usuario página 30

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• Slide the limit switch bracket along the rack until the limit switch lever is triggered (FIG. 12).
• From this position, advance the bracket by 20 mm (FIG. 13).
FIG. 12
• Fix the bracket to the rack using the dedicated set screws (FIG. 14).
FIG. 14
• Repeat the procedure for the closure limit switch.
• Move the gate into the central position (FIG. 15) and reset the motorised command as illustrated in section 4.3.3.
MAGNETIC LIMIT SWITCH
The magnetic limit switch kit is composed of an opening limit switch with black magnet and a closure limit switch with red magnet.
PAY ATTENTION NOT TO INVERT THE COLOURS DURING INSTALLATION!
• Manually move the gate into the opening position, stopping it at a distance of 3 cm from the mechanical stop (FIG.11).
• Slide the limit switch bracket with the black magnet along the rack, aligning it with the centre line of the sensor (FIG. 12).
• Maintain a distance of 10 to 30 mm inclusive between the magnet and sensor (FIG. 13).
• Fix the bracket to the rack using the dedicated set screws (FIG. 14).
• Manually move the gate into the closure position, stopping it at a distance of 3 cm from the mechanical stop.
• Slide the limit switch bracket with the red magnet along the rack, aligning it with the centre line of the sensor.
• Maintain a distance of 10 to 30 mm inclusive between the magnet and sensor (FIG. 13).
• Fix the bracket to the rack using the dedicated set screws (FIG. 14).
• Move the gate into the central position (FIG. 15) and reset the motorised command as illustrated in section 4.3.3.
30
COMUNELLO ®Copyright 2020 - All rights reserved
FIG. 13
20 mm

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fort 500Fort 600Fort 800Fort dual 1000Fort 1500Fort one