Commissioning; Preliminary Operations; Factory Calibration - Sime FUEL 25 EV Manual De Uso, Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
5

COMMISSIONING

5.1

Preliminary operations

m
CAUTION
The commissioning and initial start-up operations
must be carried out ONLY by professionally qualified
personnel who must follow the indications provided in
this manual and in the manual of the relevant boiler.
The operator must wear personal protective equip-
ment.
Prior to commissioning the appliance, remove the screws (4)
and (8) and install a vacuum gauge and a pressure gauge re-
spectively.
Then verify that:
– There is sufficient fuel in the tank.
– The fuel, thermal system and water circuit valves are open.
– The electrical connections have been made correctly.
– The exhaust pipes for combustion by-products have been ar-
ranged correctly.
– In case of TYPE B installations, the vents are adequately sized
in relation to the installed power and the combustion air inlet
of the burner is free (without splits).
5.2

Factory calibration

All the burners are adjusted and tested in the factory according to the data shown in the table and in the reference conditions specified
below.
Burner
Model
SIME FUEL 25 EV (vers. std)
SIME FUEL 35 EV (vers. std)
SIME FUEL 25 EV (vers. HE)
SIME FUEL 35 EV (vers. HE)
(*) The pump pressure is measured after an operating interval of 5 min.
Reference conditions
– Fume exhaust system: diameter 80 mm / length 1.5 m
– Room temperature: 20°C +/-5
– CO
= 12,5% ± 0,2.
2
– Altitude 0 m.a.s.l..
Burned power
+/- 4%
kW
Kg/h
GPH
27
2,25
0,55
34,8
2,90
0,65
27
2,25
0,55
34,8
2,90
0,65
– The fume exhaust system has been made correctly.
– The system has been correctly pressurised and all the expan-
sion vessels have been pre-charged.
– The control, command and safety devices are present.
4
Nozzle
Pump pres-
(Danfoss)
sure*
Spray
bar
60°H
12,0
60°H
12,0
60°H
12,0
60°H
12,0
8
Fig. 27
Air shutter adjustment
mm (+/-0,1)
3,8 +/- 0,2
5,7 +/- 0,2
3,5 +/- 0,2
5,5 +/- 0,2
51

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fuel 35 ev8118500811850181185028118503

Tabla de contenido