Cleaning The Impeller - Sime FUEL 25 EV Manual De Uso, Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
To facilitate maintenance operations, secure the burner to the boiler by inserting the fixing screw (9) through the hole (12) on the foot.
Use one of the three square-shaped grooves on the foot to secure the burner rotated in the most suitable position for performing the
required maintenance operation.
12
9
A
POSITION A
6.2.1

Cleaning the impeller

Check that there is no dust inside the impeller as this could re-
duce the combustion performance. Perform maintenance ope-
rations while being careful not to damage the fan. Check that
the impeller is properly positioned inside the burner body.
Observe the following sequence:
– loosen the screws (1) and remove the air intake duct (2);
– clean the impeller (3) and the air duct using a paintbrush;
– if necessary, dismantle the impeller and mount it back on.
A
B
Position A:
– Inspection and cleaning
of the internal impeller, if
necessary.
Position B:
– Inspection of the combu-
stion head
B
– Inspection and mainte-
nance of the nozzle
C
– Inspection and mainte-
nance of the electrode
unit.
Position C:
– Inspection and mainte-
nance of the pump
– Inspection and mainte-
nance of the coil
– Inspection and mainte-
nance of the capacitor.
C
3
Fig. 37
1
2
Fig. 38