Maintenance; Adjustments; Removing The Burner - Sime FUEL 25 EV Manual De Uso, Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6

MAINTENANCE

6.1

Adjustments

Periodic maintenance is MANDATORY BY LAW and is important
for the safety, efficient operation and long-lasting life of the
burner, while it also helps to reduce consumption and polluting
emissions.
We therefore recommend the user to entrust a professionally
qualified technician to carry out maintenance on the appliance
on an ANNUAL basis.
m
CAUTION
– The operations described below must ONLY be car-
ried out the professionally qualified personnel who
suitable accident-prevention equipment.
MUST wear
– Make sure that the temperature of the components
inside the device or of the system pipes are not too
hot (risk of burns).
– Shift the main switches of the system and of the boi-
ler to "OFF".
– Close the fuel shut-off valve.
OFF
6.2

Removing the burner

To remove the burner form the boiler, proceed as follows:
– loosen the nut (9) fastening the burner to the boiler;
– turn the burner (10) slightly to the right and extract it from
the boiler;
10
56
– loosen the two screws (1) and slide off the cover (2);
– detach the 7-pole plug (1) from the burner.
Fig. 33
9
Fig. 34
2
1
1
EN
Fig. 35
1
Fig. 36

Publicidad