6
COMMISSIONING
8
Figure: Alignment
2
Sensing range
Check the application conditions: Adjust the sensing range and the remission capability of
the object according to the corresponding diagram
operating reserve).
During this process, an object can only be detected in front of a background if the remis‐
sion capability of the object is significantly higher than that of the background or if the dis‐
tance between the object and the background is sufficiently long.
Funktionsreserve
100
90%/90%
1
18%/90%
2
10
6%/90%
3
1
0
20 0
40 0
Figure 3: Sensing range of up to 900 mm
[see figure
Funktionsreserve
100
18%/90%
10
1
60 0
80 0
1.00 0
0
Abstand in mm
Figure 4: Sensing range of up to 300 mm
3]. (x = sensing range, y =
90%/90%
1
2
10 0
20 0
30 0
Abstand in mm
8021850 | SICK
Subject to change without notice
40 0