3) Start test and wait for test to finish
4) Open the test fixture
5) Remove the tested electronics assembly
7)
Maintenance
WARNING
L
ETHAL ELECTRIC SHOCK
Deadly electrical voltage at the test probes for > 25 VAC voltage and > 60 VDC voltage!
Before servicing disconnect all affected devices from the power supply and secure (e.g.
with a sign) against unauthorised reconnection!
7.1)
Maintenance intervals
Every 50,000 cycles
Part
Lubricate gas spring bearing
and check function
Note: the service life of the gas spring
is specified by the manufacturer as
50,000 cycles. In long-term tests,
however, the gas springs have
remained effective at several times
this specified life.
Every 3 months
Part
Check test adapter for wear
Annually
Part
Protective conductor wiring
(only available with corresponding
additional function)
7.2)
Check and replace test probes
The spring-loaded test probes are subject to very different loads. A reliable signal transmission is
only possible with fully functional test probes. Conditions for reliable contact are:
no contamination on the plunger tip
no excessive wear of the points of the plunger tip
no scratches on the test probe's plunger shaft
no metal chips, particles, or other contamination on the probe plate between the probes
test probe is installed securely in the receptacle
no height differences between test probes of the same type
no bending of the test probe
correct position of the respective test probe types
The spring-loaded test probes can be removed and installed quickly without the need additional
wiring thanks to the receptacles. Specialised insertion and extract tools are available from INGUN
to replace test probes.
©
INGUN: Subject to technical changes without notice. E&OE.
!
Indication of defect
The force of the gas spring
decreases, the hold-down or
drive unit closes, or becomes
sluggish and could possibly
become blocked
Indication of defect
Moving parts with large play,
possibly abrasion or other ab-
normalities
Indication of defect
Possibly reduced protective
function
Procedure
Lubricate bearing(see Chap-
ter 7.5) Grease/lubricate test
adapter
Replace defective parts and
grease bearing of gas spring
Procedure
Clarify the cause and replace
defective parts, contact the
manufacturer if necessary
Procedure
Measurement of protective
conductor resistance (thresh-
old: 0.3 Ω) Visual inspection;
if necessary, replace defec-
tive wiring
30