No: 340932 – 4/12
Catalog Number: L2EVSE16
Country of Origin: Made in Mexico
• READ ALL INSTRUCTIONS BEFORE BEGINNING
NOTES:
Read and understand all directions contained
in this document.
Observe all local electrical and building codes.
Make sure the wall structure is capable of supporting
the charging station.
Leave this installation document with the
vehicle/home owner.
INSTALLATION
The following tools are required for a wall mount installation of
the L2EVSE16 charging station:
Wire cutters, level, drill with 1/8" and 3/4" bits, tape measure,
pencil, Phillips screwdriver, T15 Torx driver, wire nuts capable
of connecting #14 AWG stranded wire to the supply cable,
(2) #10 x 2" lag screws with sealing washers, sealing compound.
Additional equipment required (not included)
• copper supply cable (specified by NEC
• circuit breaker (specified by NEC)
• appropriate wall anchors (for studded wall or solid wall
installation)
• Applicable conduit and fittings (for solid wall installation)
Note: a 1" NPT threaded conduit inlet is supplied for bottom
feed applications.
• 3/4" NPT, threaded non-metallic cable clamp or fitting
(for rear-feed applications with non-metallic cable)
LOCATING THE CHARGING STATION
The charging station (Figure 1) should be mounted conveniently
near the electric vehicle (ev) parking location. The station is supplied
with a 24 ft. coiled charging cord with a charge connector on the
end. This connector is intended to mate with the charging port that
is located on the electric vehicle. The charging station should be
mounted in a location where there is a clear, unobstructed path to
the vehicle charging port on the car. The recommended mounting
height for the charging unit is at least 18" but not more than 48"
above the floor per NEC article 625.
Pass & Seymour
Electric Vehicle Charging Station
Installation Instructions
)
®
®
The Legrand/Pass & Seymour catalog number L2EVSE16 should be
connected only to a 240VAC or 208VAC, 60Hz, grounded branch circuit
and its installation must comply with the NEC and any local codes or
regulations.
Installation of the Legrand/Pass & Seymour catalog number L2EVSE16
must be performed by a licensed electrician.
Shock, fire, property damage, personal injury, or death may result if
these instructions are not followed.
If you have any questions about the use or installation of this product,
contact your Legrand/Pass & Seymour technical support representative
at : 800-223-4185 (or tech_support@pass-seymour.com)
There are no user serviceable parts contained in this product. Any
attempt to service this product may result in shock or fire causing
property damage, personal injury, or death.
Save these instructions for future reference.