Switch Replacement

Risk of electric shock. When servicing pump,
always disconnect power to electrical outlet and remove pump
electric cord from outlet.
Float must be able to complete its entire
cycle without interference from sidewall of basin, plumb-
ing, or any other object.
1. Mount bracket on switch housing using existing screws.
2. Slide rod into slot in bottom of switch housing. Fasten rod
into switch housing with pin.
Make sure pin holds float rod in switch hous-
ing; otherwise pump will not shut off.
NOTE: Pull gently on rod to make sure that it cannot come out
of switch housing.

TROUBLESHOOTING

SYMPTOM
Pump won't
start or run.
Pump won't
shut off.
Pump operates
but delivers
little or no water.
WA483
POSSIBLE CAUSE(S)
1. Blown fuse.
2. Low line voltage.
1. Restricted discharge
(obstacle in piping).
1. Restricted discharge
(obstacle in piping).
3. Mount switch assembly on pump using existing screws.
Make sure that nothing interferes with switch operation.
4. Mount float on rod.
5. Install rod stop on bottom of rod.
6. Run pump through one complete cycle to verify correct
switch operation.
Risk of flooding. Drainer Pre-Plumbed System
comes with the automatic float switch mounted on the motor
housing ready for operation. Do not change switch settings.
Switch is set to start at approximately 6.5" and to stop at
approximately 2".
CORRECTIVE ACTION
1. If blown, replace with fuse of proper size.
2. If voltage under recommended minimum,
check size of wiring from main switch on
property. If OK, contact power company or
hydro authority.
1. Remove obstacle in piping.
1. Remove obstacle in piping.