BDAL_IS3180_24spr_neu
Troubleshooting
Malfunction
Sensor without power
Sensor will not switch ON
Sensor will not switch OFF
Sensor keeps switching
ON/OFF
Sensor responds when it
should not
Change in sensor's reach
LED flashing rapidly
(approx. 5 x per second)
25.07.2008
15:09 Uhr
Cause
Remedy
I Fuse faulty, not switched
I New fuse, turn on power
ON, break in wiring
I Short circuit
I Check connections
I Twilight control set to night-
I Reset
time mode during daytime
operation
I Bulb faulty
I Change bulb
I Power switch OFF
I Switch ON
I Fuse faulty
I New fuse, check connection
I Detection zone not properly
I Re-adjust
targeted
I LED flashes approx. once
I Press button
a second, sensor in time
setting mode
I Continuous movement in the
I Check zone, adjusting if
detection zone
I Light being operated in the
I Change zone, or shroud
detection zone causing sen-
sor to responds as a result
of change in temperature
I Light being operated is in
I Deactivate manual override
the manual override mode
(LED ON)
I Lamp being operated in
I Change zone, shroud or
the detection zone
I Animals moving in the
I Change zone, or shroud
detection zone
I Wind is moving trees and
I Change detection zone
bushes in the detection zone
I Cars in the street are being
I Change detection zone
detected
I Sunlight is falling onto the
I Mount sensor in a sheltered
lens
I Sudden temperature changes
I Change detection zone,
due to weather (wind, rain,
snow) or air expelled from
fans, open windows
I Differing ambient tempera-
I Use shrouds to define detec-
tures
I Load connected is too high
I Reduce load or use
18
Seite 19
switch, check wiring with
voltage tester
if necessary
once
necessary, or shroud
increase distance
place or change detection
zone
change site of installation
tion zone precisely
contactor