Items supplied
EN
Introduction
Mixing together
Casting
Horizontal installation
Casting
Vertical installation
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full con-
sistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Responsibility for suitability and intended use of
this instrument rests solely with the user.
Copyright © Siemens AG 04.2014 All Rights Reserved. Technical data subject to change without prior notice.
Siemens A/S - Flow Instruments
6430 NORDBORG
DENMARK
www.siemens.com/flowdocumentation
Order no.: 083R9042
Literature no.: SFIDK.PI.027.K6.83
Potting kit (order no. 085U0220)
1 tin Sylgard 517 A, 0.5 kg
1 tin Sylgard 517 B, 0.5 kg
1 mixing utensil
1 funnel
The potting kit is used in the terminal box of a MAG 3100 sensor to obtain an IP68 10 mH
rating.
The kit must always be used if the flow-meter is to be buried or installed in a pit or chamber.
Sylgard 517 A and B Silicone Dielectric Gel is a two-component clear silicone.
At indoor temperature the mixed Sylgard is liquid for about 16 hours, and after 24 hours
turns gelatinous.
The Sylgard remains as a jelly, but can be removed or penetrated to give access to the cable
connections.
Pour the contents of tin B into tin A and mix thoroughly. Air bubbles should be avoided. The
terminal box is filled imme-diately after mixing the two components.
Ensure the cable is correctly installed and
that cable entries and plugs are properly
tightened (see handbook).
Pour the mixed Sylgard into the terminal
box ensuring the terminals and cables are
completely covered.
Check the gasket between terminal box
and cover is fitted correctly and that it is not
damaged. Mount the cover and tighten.
Ensure the cable is correctly installed and
that the cable entries are properly tightened
(see handbook). Ensure the gasket between
terminal box and cover is fitted correctly and
that it is not damaged. Mount the cover.
Dismantle one plug and pour the mixed Syl-
gard via the threaded sleeve into the termi-
nal box. Re-fit the plug and tighten both
plugs.
Not for use in hazardous areas.
INSTRUCTIONS
SITRANS F M
*083R9042-06*
O
2

Publicidad

loading

Resumen de contenidos para Siemens SITRANS F M

  • Página 1 However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Responsibility for suitability and intended use of this instrument rests solely with the user. Copyright © Siemens AG 04.2014 All Rights Reserved. Technical data subject to change without prior notice. Siemens A/S - Flow Instruments...
  • Página 2 Übereinstimmung keine Gewähr übernehmen. Die Angaben in dieser Druckschrift werden regelmäßig überprüft, notwendige Korrekturen sind in den nachfolgenden Auflagen enthalten. Der Benutzer ist allein verantwortlich für Eignung und Bestimmungszweck dieses Gerätes. Copyright © Siemens AG 04.2014 All Rights Reserved. Änderungen vorbehalten. Siemens A/S - Flow Instruments...
  • Página 3: Introducción

    El contenido de esta publicación se revisa periódicamente; si es necesario, las posibles las correcciones se incluyen en la siguiente edición. La responsabilidad relativa a la conveniencia y al uso propuesto de este instrumento es exclusivamente del usuario. Copyright © Siemens AG 04.2014 All Rights Reserved. Sujeto a cambios sin previo aviso. Siemens A/S - Flow Instruments...
  • Página 4 Si l’usage de ce manuel devait révéler des erreurs, nous en tiendrons compte et apporterons les corrections nécessaires dès la prochaine édition. La responsabilité concernant l’usage approprié et prévu de l’instrument incombe à l’utilisateur. Copyright © Siemens AG 04.2014 All Rights Reserved. Sous réserve de modifications techniques. Siemens A/S - Flow Instruments...