Uline H-1287 Manual De Instrucciones página 3

Ocultar thumbs Ver también para H-1287:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

POWER AND CONTROL WIRING CHECKS
1. Using a voltage meter, check the AC voltage
coming to the system to insure proper voltage is
present.
Plug the power cord to a 120VAC outlet. Power should
be applied to the frequency drive and foot switch.
OPERATING INSTRUCTIONS
1. Simply step on the foot pedal to start the turntable
drive motor. The foot pedal is a maintained switch.
Pressing the pedal again turns the turntable motor off.
Figure 2
SINGLE -PHASE MODELS
INPUT FROM R/L1, S/L2
LED INDICATORS
RUN/STOP
FREQUENCY
SETTING KNOB
SIGNAL SELECTION
FOR AVI TO INPUT
DC0 TO +10V OR 4 TO
20 mA
CONTROL TERMINAL
PAGE 3 OF 21
SYSTEM SET-UP CONTINUED
FREQUENCY DRIVE ADJUSTMENT
AC LINE
INPUT
TERMINALS
R/L1 S/L2 T/L3
RUN
FWD
REW
RUN
STOP
MIN.
MAX.
RA RC +10V A/1 D1 D2 D3 D4 GND
U/T1 V/T2 W/T3
MOTOR
CONNECTIONS
TURNTABLE SPEED ADJUSTMENT
1. The turntable speed is adjusted by a built-in
potentiometer dial on the AC frequency drive.
Turn clockwise to increase, counter-clockwise to
decrease. The maximum turntable speed is 12
rotation-per-minute (RPM).
GROUNDING
WIRE GAUGE: 12-20 AWG
TORQUE: 5 KGF-CM
UP/DOWN
STOP
FUNCTION DISPLAY KEY
MODE
RESET
DATA COMMUNICATION KEY
ENTER
NFX
9000
MOTOR CAPACITY AND INPUT
0.5 HP
POWER
230V 1 PHASE
WARNING
RS-485 COMMUNICATION PORT
RS-485
WIRE GAUGE: 12-20 AWG
TORQUE: 5 KGF-CM
GROUNDING
0521 IH-1287

Publicidad

Tabla de contenido
loading

Tabla de contenido