3. Replacement
Warning
Before removing the terminal box
cover, make sure that the electricity
supply has been switched off and that
it cannot be accidentally switched on.
1. Switch off the electricity supply to the pump by
means of the external mains switch. The green
indicator light on the terminal box must be off.
2. Remove the terminal box cover.
3. Remove all wires from the terminal block.
4. Replace the existing module in the terminal box
by the new one, see fig. 2.
For removal/fitting of the three screws shown,
use the screwdriver supplied with the module.
5. Replace the wiring diagram in the terminal box
cover by the diagram supplied with the module,
see fig. 3.
6. Connect the supply wires as shown in
(at the end of these instructions).
7. Fit the terminal box cover.
8. Switch on the electricity supply. Check correct
connection by means of the indicator lights, see
the table in section
2. Indicator
Fig. A
lights.
Fig. 2
Fig. 3