8016605
Subject to change without notice
600
(23.62)
500
(19.69)
Non-transparent trays
400
(15.75)
300
(11.81)
200
(7.87)
100
(3.94)
0
100
200
300
(7.87) (11.81) (15.75) (19.69) (23.62) (27.56)
(3.94)
Adjustment range background (x)
Legend:
x: Sensing range max. in mm (adjustment range background)
= Distance sensor / background
y: Sensing range in mm (detection range object)
= Maximum distance sensor / front edge of the object
Minimum distance sensor / background : 150 mm*
*) Referring to the background with 90 % remission equivalent to standard white DIN 5033 (i.e. glass-bead blasted
stainless steel). The use of a shiny background can increase the minimum distance to the background (i.e. brushed
and pickled stainless steel, minimum distance sensor to background: 300 mm).
Image 19: H
Montar o sensor numa cantoneira de fixação adequada (ver linha de acessórios da SICK).
Observar o torque de aperto máximo permitido de 2.0 Nm para o sensor.
Observar a direção preferencial do objeto em relação ao sensor [cp. A].
Para garantir a maior segurança de detecção possível, para a montagem do sensor são reco‐
mendadas as seguintes instalações para a detecção de objetos transparentes:
Detecção de Trays transparentes: montagem vertical
Detecção de garrafas transparentes: montagem horizontal
A conexão dos sensores deve ser realizada em estado desenergizado (V
de conexão, devem ser observadas as informações contidas nos gráficos [cp. B]:
– Conector: Pin-out
– Cabo: Cor dos fios
Image 20: B: WTF12G-3P/Nxxxx
Image 21: B: WTF12G-3Kxxxx
Instalar ou ligar a alimentação de tensão (V
xões elétricas. O indicador LED verde está aceso no sensor.
Explicações relativas ao esquema de conexões (Gráfico B):
Transparent trays
400
500
600
700
> 0 V) somente após a conclusão de todas as cone‐
S
Colocação em funcionamento
= 0 V). Conforme o tipo
S
WTF12G TranspaTect | SICK