TESY CN04 EIS W Instrucciones Para El Uso página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
the temperature setting either up or down. If you don't
press any button for 5 seconds, the new setting will be
stored and the appliance with automatically go into
"Heating" mode. If you keep pressed any of the buttons
or
for more than 0.7 seconds, the value of the set
temperature will start increasing or decreasing by 4 units
per second. The temperature setting ranges from 10 to 30
degrees Celsius.
"Delayed start" of the panel convector
When the convector is in Off mode, by pressing the
"Timer" button you can enter a specific time after
which the appliance will automatically go in "Heating"
mode. This mode is indicated by a blinking yellow
LED and inactive red LED. The digital display will show
the room temperature when the Temperature LED is
lit, and it will show the remaining time in hours until
"Heating" mode will be activated and this will be
indicated with a lit Timer LED. Upon activating this
mode the yellow LED becomes lit, and the display
starts flashing and showing the entered time in hours
until the convector will be automatically switched
on. Initially the display will show 12 hours, and by
using the
or
buttons you can adjust the desired
time. If you keep pressed any of the buttons
for more than 0.7 seconds, the value of the set
time will start increasing or decreasing by 4 units per
second. If you don't press any button for 5 seconds,
or if you press the Timer button, the regulator will
automatically go into "Delayed start" mode. If you
enter time 00, this mode will not be activated. When
the "Delayed start" mode is already active, if you
press the "Timer" button again, you can correct the
remaining time in both possible directions. After
setting the time, the appliance goes into "Delayed
start" mode with the display showing the temperature
and the hours remaining until the appliance will
switch to "Heating" mode. You can exit this mode by
pressing the "On/Off" button. Then the convector will
go into "Heating" mode. The "Delayed start" mode can
be set within a range from 01 to 96 hours.
Switching off "Heating" mode
You can exit "Heating" mode by pressing the "On/Off"
button. Then the heater will be switched off, and if it has
been on by then, the red LED will go out. The display will
continue showing the room temperature.
"Anti-frost function"
If the room temperature falls below 5 degrees Celsius
and the convector is off (the red LED is not lit, but the
mechanical switch is in position "I" (On)
be automatically switched on in order to prevent from
freezing.
Entering a temperature correction for the
temperature sensor does not apply to this
function.
English
Enabling and disabling the anti-frost function:
this function is enabled by default
to disable this function, the convector must be in
"Off" mode, when you press the
button for three seconds the display will show a
blinking "ON", and by pressing the
will reach the "OFF" position, then you need to wait
for 3 seconds and the function will automatically go
in "OFF" mode.
to enable this function again, the convector must
be in "Off" mode, when you press the
Off" button for three seconds the display will show
a blinking "OFF", and by pressing the
will reach the "ON" position, then you need to wait
for 3 seconds and the function will automatically go
in "ON" mode.
"Temperature correction for the sensor" function
Due to the specifics of the temperature profile in some
premises there may be difference from the temperature
shown on the display and the actually measured
temperature in the various locations of the heating
appliance in the room.
See the temperature shown on the display of the
or
appliance
Measure the temperature at a place where the
temperature is "comfortable" enough for you
(usually at a height of 60 cm from the floor, in
sitting positon). If you find a difference within a
range of ±4°С, you can set the necessary correction
in the convector's menu (It is important to
note that this function can be set only after the
temperature has become the same all around
the room, and depending on the room type, the
minimum required time is 7 hours) by entering
the temperature difference resulting between the
value on the display and the actually measured
temperature.
user of the electric convector in the room which it is in. A
temperature difference greater than ±4 °C from the measured
temperature in a specific location in the room indicates that
the room where you use the convector in is not well insulated
or the temperature is not the same all around the room.
Example: a convector in a room on a stone floor – the
convector displays 18°С (the set temperature is 22°С), the
actually measured temperature (feeling of reached comfort
temperature) is 22°С at a height of 60 cm from the floor - >
in this case the convector continues to overheat the room
(this is a direct energy loss, but the convector cannot reach
), the heater will
the set temperature because it measures the temperature
at a low height close to the floor) and it will never switch
off. In this case a temperature correction of +4°С needs to
be applied to the sensor, thus the convector will display
22°С and it will start switching off, and eventually it will
maintain the set temperature of 22°С).
Note: This function is used with the purpose of providing
better temperature comfort and energy saving for the
Operation and Storage Manual
EN
and "On/Off"
button you
and "On/
button you
5

Publicidad

Tabla de contenido
loading

Tabla de contenido