Flex Blower only
CAUTION
All electrical wiring should be done by a qualified
person(s) in accordance with all applicable codes
and standards.
• This downdraft blower using the Flex Blower (purchase
separately) draws 3.0 Amps and requires a
120 VAC, 60 Hz circuit.
• The unit has a 30 in. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will
allow the unit's power cord to reach.
• Install electrical box according to local codes.
18a
Mount a standard wiring box, with 3-pronged receptacle, within reach
of downdraft's power cord. (Run appropriate power cable and connect it
to receptacle.)
19a
I
Remove electrical panel (I) cover and route blower wire into wiring box.
Electrical Wiring Installation
20a
Connect blower wires to wires in electrical panel. Replace electrical
panel cover.
21a
Plug electrical panel cable into lower receptacle on side of downdraft.
22a
Plug downdraft's power cord into outlet.
Note: Make sure that power cord is routed away from the heat
generated by the cooktop.
17
Green (ground)
Green (ground)
White White (neutral)
White White (neutral)
Blue Blue (low 1)
Blue Blue (low 1)
Red Gray (med 2)
Red Gray (med 2)
Orange Orange (med- high)
Orange Orange (med- high)
Black Black (high 4)
Black Black (high 4)