Descargar Imprimir esta página

Hansgrohe AXOR Starck 10020 Serie Manual Del Usuario página 17

Ocultar thumbs Ver también para AXOR Starck 10020 Serie:

Publicidad

Important! The fitting must be installed, flushed
and tested after the valid norms!
Assembly
1
Flush through the supply pipes.
2
Place the mixer including the sealing
washer in position on the sink.
3
Slide the fixation piece including the washer
over the threaded pins and tighten the nuts.
4
Connect the supply pipes to the isolation
valves; cold right - hot left.
5
Connect the pull rod to the pop-up waste.
The pressures of the cold and hot water
connections must be balanced.
Technical Data
This mixer series-produced with
waterdimmer® (flow limiter).
Rate of flow with waterdimmer:
Rate of flow without waterdimmer:
Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
English
5 l/min 0,3 MPa
10 l/min 0,3 MPa
max. 1 MPa
0,1 – 0,5
1,6 MPa
max. 80° C
65° C
Hansgrohe single lever mixers can be used
together with hydraulically and thermically
controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa.
If the continuous water heater causes any
problems or there is not enough flow of water,
the waterdimmer® (5a) located behind the
aerator must be removed.
Spare parts see page 4
1
flange
2
handle
3
cartridge cpl.
4
aerator cpl.
5
pull rod
6
connection hose
7
selector
8
extension hose 300 mm
9
lever arm cpl. 200 mm
lever arm cpl. 340 mm
Special accessories
X special tool set 58085000
(order as an extra)
XXX = Colors
000 chrome plated
810 satinox®
96427XXX
10090XXX
96339000
94005XXX
94006XXX
96316000
13961000
13098000
96007000
96324000
5

Publicidad

loading

Este manual también es adecuado para:

Axor starck 10023000Axor starck 10028000