Technical Data; Control Panel - Milwaukee Digital Level Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24

TECHNICAL DATA

Rated Power input ..................................................................
Charging time .........................................................................
Battery voltage........................................................................
USB-input ...............................................................................
Electronic Module Accuracy at 0° and 90° (20° ± 5°) .............
Electronic Module Accuracy between 1° and 89° (20° ± 5°) ...
Lenght.....................................................................................
Weight ...................................................................................
Protection class ......................................................................
Recommended ambient operating temperature .....................
Recommended ambient charging temperature ......................
Recommended battery types..................................................
Recommemded USB power supply........................................
WARNING! Read all safety warnings and all
instructions. Failure to follow the warnings and instructions
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS BATTERY
Only use Milwaukee Type L4 B2 rechargeable batteries.
Remove the battery pack before starting any work on the
appliance.
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors off er to
retrieve old batteries to protect our environment.
Do not store the battery pack together with metal objects
(short circuit risk).
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
water. In case of eye contact rinse thoroughly for at least 10
minutes and immediately seek medical attention.
Warning! To reduce the risk of fi re, personal injury, and
product damage due to a short circuit, never immerse your
tool, battery pack or charger in fl uid or al-low a fl uid to fl ow
inside them. Corrosive or conductive fl uids, such as
seawater, certain industrial chemicals, and bleach or bleach
containing products, etc., Can cause a short circuit.
SPECIFIED CONDITIONS OF USE
The Digital Level is intended for quick and precise
measuring of inclines.
Do not use this product in any other way as stated for
normal use.

CONTROL PANEL

Menu up
Menu /Select
Menu down
12
ENGLISH
470 207 - Digital Level.indd 12
470 207 - Digital Level.indd 12
DIGITAL LEVEL
DIGITAL LEVEL 60
................................1,5 W ......................1,5 W
...................................2 h ..........................2 h
...................................4 V ..........................4 V
...... 5 V DC; 0,1 A – 2,1 A 5 V DC; 0,1 A – 2,1 A
...........................± 0,03 ° ...................± 0,03 °
.............................± 0,1 ° .....................± 0,1 °
...............................600 mm.................1200 mm
..............................0,95 kg ......................1,7 kg
........................... IP 65 ............................ IP 65
............................................-10...+50 °C
............................................ +5...+40 °C
.................................................L4 B2
........................................... USB Micro B
POWER
Press and hold
Press and hold
The level will go to sleep after 3 minutes of inactivity. The
level can be turned back on again by moving the level or
pressing any button. The level will turn off after an additional
10 minutes of inactivity.
The level will go to sleep immediately if it is not upright, and
turn off after an additional 10 minutes of unuse.
AUDIO LEVELLING
Double tap the power button to turn the sound on or off .
When on, the level will sound when it is within 10° of the
target. The beats per minute will change once you are within
5°. If the target is crossed, the pitch will also change,
indicating a passed target. When a target is reached within
the tolerance range set by the user, the on target tone will
play.
MENU
Press
Press
Press
To exit, select exit on the menu screen or press and
hold
Description
Mode
Sensitivity
Tolerance
Power
Sound
Settings
PIN
Power Mode
Language
DIGITAL LEVEL 120
to turn on the level.
to turn off the level.
to access the menu.
again to cycle through the menu screens
to modify settings.
.
Function
Changes the level's measurement type
between angle, percent, in/ft, mm/m
Changes the precision of the mode
selected between whole, tenth, hundredth
Adjusts the start of color activation as the
level approaches the desired target
Turns sound on or off
Expands to more menus and off ers
Exit to working mode
Changes the display between High
Contrast, Auto and Power Save
Changes the language settings