Descaling Program - length: approximately 22 minutes
Warning! To meet the guarantee conditions, it is essential to perform the descaling cycle when the appliance
requests it. Carefully follow the instructions displayed on the screen. You may continue to use the appliance,
but it is advised to perform the cycle as soon as possible.
Only use KRUPS descaling products (F054) (25). You can obtain descaling products from KRUPS After-Sales Service
centres.
No liability shall be incurred in the case of damage to the appliance caused by the use of other products.
Make sure to perform the entire descaling program to prevent any risk of poisoning.
The descaling cycle is an intermittent cycle — do not place hands under the steam nozzle during the cycle.
Make sure to properly protect your counter top during the descaling cycles, particularly if it is made of marble, stone
or wood.
If your product is equipped with our Claris - Aqua Filter System F088 cartridge, please remove this cartridge before
starting the descaling operation.
The quantity of scale deposited depends on the hardness of the water used. When a descaling is necessary, the
appliance advises you by periodically displaying a warning message.
To perform the descaling program, you will need a container that holds at least 0.6 L and a pouch of KRUPS descaling
agent.
When the message "Descaling required" is displayed, you may start the automatic descaling program by pressing OK.
Please follow the instructions displayed on the screen, making sure to dissolve the contents of the pouch.
The descaling cycle is comprised of 3 parts: the descaling phase itself, followed by 2 rinse phases.
If you unplug your machine during descaling or in the event of a power failure, the descaling program will
resume at the step underway during the incident. It will not be possible to defer this operation.
This is mandatory for reasons related to water circuit rinsing.
CLEANING OF THE OTC (ONE TOUCH CAPPUCCINO) SYSTEM
To perform this cleaning program, you will need a container (at least 0.6 L) and some KRUPS XS 4000 cleaning liquid
(26).
Turn the button of the cover of the OTC system to the Latte recipe position
You may launch a cleaning program by going to the maintenance menu and then pressing OTC Cleaning. Follow the
instructions on the screen.
THE OTC (ONE TOUCH CAPPUCCINO) SYSTEM
To disassemble the system, follow the instructions below:
Remove the flexible hose from the opening of the pot and from the drinks spout (27).
Turn and remove the settings button of the cover (28) and run it under water (29). Then reposition it (30).
Lift the lever (31) and remove the cartridge (32).
Remove the black silicone body from the cartridge (33), and remove the plastic part (34) to run it under water (35).
Remove the air tip (36) and run it under water as you pinch its lips (37).
Run the entire silicone part under water (38).
Take the disassembly tool and unscrew the steam nozzle tip (39).
Use the pin (X) to clean the steam nozzle tip (40). Screw it back in.
Reposition all parts (41-42-43-44).
Remove the milk delivery hose from the cover of the pot (45), run it under water, and then reposition it.
Re-assemble the OTC system on the milk pot (46).
The manual cleaning of the OTC system is now performed.
34
MANUAL MAINTENANCE OF
(17).