6 Putting into operation
5 Check the clearance between the proximity switch (1) and the transmitter disc (2) and correct it if
necessary.
6 Loosen the screws (5).
7 Move the proximity switch (1) axially and tighten the screws (5).
8 Check the freewheeling of the transmitter disc (2) by turning the motor.
6.8 Adjusting the injection unit quantity
Cleaning unit
1
Injection and air blast unit
2
Adjusting the injection unit fluid quantity
Fig. 9
For adjusting the spray quantity, the system must be provided with compressed air. In order to assess the
function and the spray quantity, the solenoid valve Y3 must be switched.
Fig. 13 Connecting the pneumatic system on page EN-16
Danger of crushing
Limbs can be drawn in and crushed by moving parts (milling cutter, clamping unit).
• Do not reach between moving parts.
Damage to the eyes
Sprayed release agent may damage the eyes.
• Wear safety goggles.
• Only adjust release agent by switching the solenoid valve Y3.
1 Connect siphon hose (5) to the release agent cylinder if necessary.
2 Switch on Y4.
3 Adjust the quantity of release agent by means of the adjusting screw (4).
4 Switch off Y4.
EN - 12
1
2
6
5
Extraction hose (release agent)
3
Adjusting screw
4
WARNING
WARNING
3
4
Extraction hose (release agent) 6
5
BRS-LCi
Supply line (compressed-air
motor)