MAINTENANCE AND CARE OF THE SCBA APPARATUS
(9)
Push out the spindle (3) in the pressure reducer holder (see Fig. 9).
(10) Remove pressure reducer from the carrying plate, do not push up the stop
spring (2).
1
Fig. 9
Remove pressure
reducer
1
U-clip
2
Stop spring
3
Spindle
Do not remove the U-clip and hoses after removal of the pressure
reducer.
(11) Set slide carrying plate (see Point 3.3) to smallest position, push lock
(Pos. 10 in Figure 1) and then push slide plate further until removed.
(12) Clean carrying plate with cylinder strap,as well as slide plate at max. 60°C.
(13) Clean harness in a suitable washing machine at max. 60°C.
(14) Clean lines, pressure reducer and pressure gauge by hand.
Attention!
Do not submerge pressure reducer in water. This can affect the
functioning of the pressure reducer.
(15) Completely dry all compressed air breathing apparatus components in a
drying cabinet at max. 60°C.
16
2
3
AirMaXX SL
1
Fig. 10 Remove line
1
Stop pin for
Multi-channel line
MSA
GB