System Description; Technical Data - Dustcontrol 1600 Manual Original

Tabla de contenido

Publicidad

System Description

Radial fan
Dustcontrol's fans are so called radial fans. Th e air is
introduced into the fan at the centre of the fan wheel and
is forced to the fan housing and through the outlet by the
centrifugal force.

Technical data

Dimensions:
Th e capacity curves have been measured and are sta-
ted empirically. Outlet pressure losses from a normal
outlet (silencer, back-fl ow valve/bend) have been ac-
counted for in the curve. Additional equipment such
as a diff user can result in increased pressure loss and
must be taken into consideration.
Stated air-fl ows are for standard air(101.3 kPa@ 20o
C).
Th e stated curves are for negative application, all
pressures stated are assumed to be below relative
atmospheric pressure at sea level. Th ese devices can
also be used for positive pressure application and will
generate a greater pressure diff erential.
2014-10-27
Direct driven
Th e fans are direct driven.
Silencing
Th e fan is equipped with vibration isolators and high
quality sound insulation. External inline silencing on the
outlet can be installed as required.
PART NO
Hz
400 V
50
230 V
50
460 V US/CAN 60
TECHNICAL DATA
50Hz
Pump RPM
rpm
3000
Weight ca
kg
Max dp
kPa
Max Q
m
3
/h
Sound Level* dB(A)
Inlet/Outlet
mm
* with exhaust silencer, 1 m.
Capacity and Power Consumption
kPa
Pu
8
4
0
1000
10
20
kW
P
Figure shows available capacity in an extraction system.
RAF 1600/2500 - 11
RAF 1600
RAF 2500
112000
7,5 kW
112100
112002
7,5 kW
112102
112007
10 HP
112107
RAF 1600
RAF 2500
60Hz
50Hz
3600
3000
290
330
7.7
9.3
2000
3500
68
70
200/160
200/160
RAF 1600
2000
3000
RAF 1600
Part No 9053/9054
15 kW
15 kW
20 HP
60Hz
3600
RAF 2500
Q
m
3
/h
RAF 2500

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

250090539054

Tabla de contenido