Description
+
ON
ON/+ OFF/-
Control button
OFF
LEARN button
Operation
The dimmer switch enables :
• Local : control of the lighting points linked to its terminals :
using the ON, OFF button
- illumination by a short press on the ON button
- increasing light level by a long press on the ON button
- switch off by a short press on the OFF button
- decreasing light level by a long press on the OFF button
using buttons 1 and 2
- illumination to 66% (factory set level) by a short press on button 1
- illumination to 33% (factory set level) by a short press on button 2
- increasing light level by a long press on button 1
- decreasing light level by a long press on button 2
• At receiver (actor) : the dimmer switch can take part in 32 different scenarios, by locally executing controls coming from
other transmitters: ON, OFF , dimming or illumination to preset levels.
Infrared cell
Charge status
indicator (blue)
+
1
1/+ 2/-
Control button
2
First LED comes
on red if protection
device
LEARN indicator
15
16

Factory settings

When first powered up, pressing the ON
or OFF buttons controls all the lighting
points of the "In One by Legrand" instal-
lation.
This option is provided so that the
correct operation and connection of all
the lighting fixtures can be checked.
Pressing Learn
(1)
twice cancels this
general control function.
Pressing Learn
(1)
twice cancels this
general control function.
(1)
Programming or learning button.