6
FUNCTION SWITCH-2
If multiple cameras are connected to a sequential
switcher in auto switch mode, the camera in the internal
sync mode causes skip every time it moves to another
scene. However, this can be solved by positioning the
L/L switch to EXT and using the level bar to adjust the
vertical sync phasing.
- INT: It operates in the internal synchronization mode.
- EXT: it operates in the power synchronization mode.
※ If your camera uses DC 12V for power source,
it operates in the internal mode regardless of the
position (EXT/INT) of the L/L switch.
7
DC IRIS Level Bar
Used to adjust the iris level of this level bar using a
screwdriver.
- Anti-clockwise: Decreases the luminance level.
- Clockwise: Increases the luminance level.
- The IRIS range of the DC lens is about between
80IRE and120IRE. In other words, the DC lens
adopts a variable range limitation system, rather
than IRIS Full Open/Close system.
- Depending on the type of the lens used that
allows setting the value below 75 IRE may cause
IRIS hunting. Therefore, make sure that the
range is set to an appropriate level (higher than
80 IRE).
8
Video Out Port
Connected to the Video Out port of a monitor.
The video signal is output via this port.
10