10. Specifications
Specifications
Electrical connection
Short-circuit resistance
Reverse polarity protection
Insulation voltage
Materials
Wetted parts
Non-wetted parts
CE conformity
Pressure equipment directive
RoHS directive
EMC directive, EN 61326 emission (group 1, class B) and interference immunity (industrial application)
The existence of strong electromagnetic fields in a frequency range of < 2.7 GHz can result in increased measuring errors up to 1 %. Do
not install the instruments in the vicinity of strong electromagnetic sources of interference (e.g. transmitting devices, radio equipment),
or use sheath current filters where applicable.
For further specifications see WIKA data sheet PE 81.01 and the order documentation.
WIKA operating instructions pressure transmitter, model S-10
S+ vs. U-
U
vs. U-
+
DC 500 V
Measuring ranges ≤ 25 bar [≤ 400 psi]: 316Ti
Measruing ranges > 25 bar [> 400 psi]: 316Ti and S13800
Case
Internal pressure transmission medium
Clamping nut
Angular connector
O-rings at the clamping nut
Flat gasket
Stainless steel
Measuring ranges ≤ 25 bar [≤ 400 psi]:
synthetic oil
Measuring ranges > 25 bar [> 400 psi]: dry
measuring cell
PA
PA
NBR
VMQ
EN
23