Ferroli BLUEHELIX TECH RRT 28 C Instrucciones De Uso, Instalación Y Mantenimiento página 167

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BLUEHELIX TECH RRT 28 C
Connection with coaxial pipes
fig. 21 - Examples of connection with coaxial pipes (
Table. 3- Max. length coaxial ducts
Max. permissible length (horizontal)
Max. permissible length (vertical)
Reduction factor 90° bend
Reduction factor 45° bend
For coaxial connection, fit the unit with one of the following starting accessories. For the wall hole dimensions, refer to
the figure on the cover. Any horizontal sections of the fume exhaust must be kept sloping slightly towards the boiler, to
prevent possible condensate from flowing back towards the outside and causing dripping.
Ø 100
Ø 60
041083X0
Table. 4 - Max. length of coaxial pipes
Max. permissible length
(horizontal)
Max. permissible length
(vertical)
Reduction factor
90° bend
Reduction factor
45° bend
EN
Coaxial 60/100
Ø 127
Ø 80
041006X0
fig. 22- Starting accessories for coaxial ducts
Coaxial 60/100
cod. 3541N260 - Rev. 04 - 04/2018
= Air /
= Fumes)
7 m
8 m
1 m
0.5 m
041084X0
7 m
8 m
1 m
0.5 m
Coaxial 80/125
20 m
0.5 m
0.25 m
Coaxial 80/125
28 m
0.5 m
0.25 m
167

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido