Ferroli BLUEHELIX TECH RRT 28 C Instrucciones De Uso, Instalación Y Mantenimiento página 181

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BLUEHELIX TECH RRT 28 C
"Sc" - Combustion Control Parameters Menu
ONLY QUALIFIED PERSONNEL CAN ACCESS THE "SC" MENU AND MODIFY THE RELEVANT PARAMETERS.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing order. Press the DHW buttons to
view or modify the value of a parameter. To save the edited parameter press either the heating"+" or "-" button (details
3 and 4 - fig. 1).
Contents Description
Sc01
Gas type selection
Sc02
Ignition gas calibration
Sc03
Ignition power
Sc04
Flue length
Sc05
Minimum power calibration
Sc06
Minimum gas valve calibration
Sc07
Flame ionization signal
Sc08
Current power ref. DHW
Sc09
MAX ionization value
Sc10
Minimum ionization value during ignition
Sc11
Ignition time
Sc12*
Ionization reduction value (BASE)
Sc13**
Ionization reduction value (min.)
Sc14
Internal error K1
Sc15
100% CALIBRATION
Sc16
DO NOT MODIFY.
PARAMETERS "SC12" AND "SC13" MUST BE MODIFIED, IF STRICTLY NECESSARY, BY QUALIFIED PERSON-
NEL AND ONLY WHEN THE CO
on page 200. CARRY OUT THE PROCEDURE AFTER AT LEAST 500 HOURS OF BOILER OPERATION.
* SC12 regulates the CO
CO
decreases; by decreasing the parameter value the CO
2
** SC13 regulates the CO
the parameter value the CO
EN
Functional description
Allows the change of gas type. See "Gas conversion" on
page 173
Allows the amount of gas to be increased or decreased in
the ignition phase in case of difficult starting.
Allows the fan speed to be increased or decreased in the
ignition phase in case of difficult starting.
Allows the boiler to be arranged according to the width and
length of the flue used. To be used only with Ø50 or Ø60
flues. See fig. 26.
Allows the minimum power to be increased, if necessary.
Self-adaptive parameter. DO NOT MODIFY.
Displays the actual ionization current signal.
Displays the actual power referred to maximum power in
DHW.
Displays the maximum ionization value reached.
Displays the minimum ionsation value reached during the
ignition phase.
Displays the time from fan activation to ionization.
Allows the adjustment of CO
mum and minimum power, translating the entire value
curve.
Allows the adjustment of CO
Displays the SCOT system error code.
Allows 100% Calibration (see "100% calibration" on
page 175) when replacing some components (see
"Extraordinary maintenance and replacement of compo-
nents" on page 186)
VALUES ARE OUTSIDE THE RANGE INDICATED IN "- Technical data table"
2
at the same time at maximum and minimum power. By increasing the parameter value the
2
at minimum power. By increasing the parameter value the CO
2
increases.
2
cod. 3541N260 - Rev. 04 - 04/2018
at the same time as maxi-
2
at minimum power.
2
increases.
2
Range
Default
na / LP
na
-9 ÷ 20
0
-16 ÷ 14
0
-2 ÷ 13
0
0 ÷ 25
0
Read only
Read only
Read only
Read only
Read only
-5 ÷ 10
0
-5 ÷ 10
0
Read only
0 - CAL
0
decreases; by decreasing
2
181

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido