Ferroli BLUEHELIX TECH RRT 28 C Instrucciones De Uso, Instalación Y Mantenimiento página 187

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BLUEHELIX TECH RRT 28 C
Plate heat exchanger
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
3
2
Isolate the boiler by operating the DHW inlet and system shut-off valves.
Open a faucet to drain the domestic hot water.
Rotate the box on the panel
Drain the water in the boiler through the drain faucet (see *** 'System draining' on page 161 ***)
Undo the screws "2"
Move the plate heat exchanger back and slide it to the left.
Remove the heat exchanger as shown in the figure
When refitting the plate heat exchanger, make sure the arrows (indicating: HEATING) are pointing downwards.
Circulating pump
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
2
1
fig. 37
Disconnect the power supply and turn off the gas cock ahead of the valve.
Electrically disconnect the circulating pump, releasing the connections by raising the detail "1" of fig. 37.
Drain the water in the boiler (see "System draining" on page 161).
Unscrew and remove the circulating pump motor assembly (fig. 39)
EN
2
1
fig. 36- Plate-type exchanger replacement/maintenance
fig. 38
cod. 3541N260 - Rev. 04 - 04/2018
3
4
fig. 39
187

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido