3-21
Slide belt over motor shaft (H).
3-24
The agitator brush roll
When to replace
When agitator brush roll brushes are
worn, the agitator brush roll should
be replaced.
Disconnect cleaner from electrical
outlet.
WARNING: Agitator brush roll can
start suddenly. Unplug cleaner
before turning it over.
What to buy
When purchasing a new agitator,
ask for HOOVER part No.
2BEA131001900.
To check condition of brushes,
move edge of a card across bottom
plate while turning agitator brush
roll. To maintain cleaning effective-
ness, replace agitator brush roll if
brushes do not touch card.
To remove agitator, follow Items 3-11
through 3-16.
Install new agitator brush roll follow-
ing Items 3-19 through 3-23.
3-22
H
Align belt between "U" shaped
posts.
Reposition hood and replace 2 hood
screws.
Lubrication
The motor is equipped with bear-
ings that contain sufficient lubrica-
tion for the life of the motor. The
addition of lubricant could cause
damage. Therefore, do not add
lubricant to motor bearings.
The agitator brush roll is equipped
with two ball bearings that should
be lubricated periodically by a
Hoover Sales and Service Center or
an Authorized Hoover Warranty
Service Dealer.
3-23
With bottom of cleaner facing up,
replace 2 bottom screws.
Continued
11