vertical lines.
6. During transportation move the switch (3) into position OFF.
Place the instrument into the soft bag or case. Do not drop the
instrument during transportation.
Application of the detector
Use detectore mode when operating in
bright sunlight. Press button (3) to activate this mode. Place
the detector to the approximate location of the beam. Follow
the instruction while searching
laser beam.
To check the accuracy of line laser level
To check the accuracy of line laser level (slope of plane)
Place laser level on the tripod 5m away from the wall so the
horizontal laser line will be directed to the wall. Switch on
the power. The instrument starts to self-level. Mark point A on
the wall to show the contact of laser beam with the wall. Turn the
instrument by 90° and mark points В, С, D on the wall. Measure
distance "h" between the highest and lowest points (these are A
and D points in the picture). If "h"is ≤ 6 mm, the measurement
accuracy is good. If "h" exceeds 6 mm, apply service center.
To check plumb
Choose a wall and set laser 5 m away from the wall. Hang
a plumb with the length 2.5 m on the wall. Turn on the
laser and make the vertical laser line meet the point of
the plumb. The accuracy of the line is in the range if the
vertical line doesn't exceed (up or down) the accuracy that
is shown in the specifications (±3 mm/10 m). If the accu-
racy isn't corresponding with claimed accuracy, contact the
authorized service center.
Note: Because of construction of laser emitter laser beam
4
may be unhomogeneous and has different intensity of
brightness along the perimeter in different light conditions.
Unhomogeneous of laser beam: laser patch of light but
the center of laser beam is identified. Different laser beam
brightness: difference of intensity is up to 50%.
Care and cleaning
Please handle measuring instrument with care. Clean with
soft cloth only after any use. If necessary damp cloth with
some water. If instrument is wet clean and dry it carefully.
5