drop the instrument during transportation.
Application of the detector
Use detectore mode when operating in
bright sunlight. Press button (2) to activate this mode. Indica-
tor (4) lights up. Place the detector to the approximate
location of the beam. Follow the instruction while searching
laser beam.
To check the accuracy of line laser level
To check the accuracy of line laser level (slope of plane)
Set up the instrument between two walls, the distance is 5 m.
Turn on the Cross Line Laser and mark the point of cross
laser line on the wall.
Set up the instrument 0,5-0,7m away from the wall and make,
as described above, the same masrks. If the difference {a1-
b2} and {b1-b2} is less then the value of "accuracy" (see spe-
sifications), there is no need in calibration.
Example: when you check the accuracy of Cross Line Laser
the difference is {a1-a2}=5 mm and {b1-b2}=7 mm. The
instrument's error: {b1-b2}-{a1-a2}=7-5=2 mm. Now you can
compare this error with standard error.
If the accuracy of Cross Line Laser isn't corresponding with
claimed accuracy, contact the authorized service center.
To check level
Choose a wall and set laser 5M away from the wall. Turn on
the laser and cross laser line is marked A on the wall. Find
another point M on the horizontal line, the distance is around
2.5m. Swivel the laser, and another cross point of cross laser
4
line is marked B.
Please note the distance of B to A should be 5m.
Measure the distance between M to cross laser lune, if the
difference is over 3mm, the laser is out of calibration, please
contact with seller to calibrate the laser.
To check plumb
Choose a wall and set laser 5m away from the wall. Mark
point A on the wall, please note the distance from point A
to ground should be 3m. Hang a plumb line from A point to
ground and find a plumb point B on ground. turn on the laser
and make the vertical laser line meet the point B, along the
GreenLiner 2V / 4V
5
6
5