Translation of the original instructions
•
Charging system test result with consumers running
Case
High start-up voltage when testing with
consumers on consumers on
Normal starting voltage when testing
with consumers on consumers on Low
starting voltage when testing with the
test is carried out with the consumers
on
Low starting voltage when testing with
consumers on
9. Press «ENTER» when the system test is completed. Switch off all consumers (heating, headlights...) Press «ENTER»
to read the test results.
VEHICLE TEST
This is a combination of battery test and system test. By choosing «vehicle test» the tester automatically carries out
all the tests. The test results are displayed on a single ticket. Refer to the test procedures above or follow the instruc-
tions on the screen.
PAPER REPLACEMENT
A. Open the transparent cover.
MAINTENANCE
Examples
Display switched off
Printing fault
Insufficient internal battery
12
PBT 700
Results displayed
ALT. CHARGE
DES VOLTS
xx.xx V HAUT
ALT. CHARGE
DES VOLTS
xx.xx V NORMAL
ALT. CHARGE
DES VOLTS
xx.xx V BAS
B. Place a new roll of
paper in the compartment.
Check that the device is properly connected. The battery voltage is not high enough
to perform the test (<1.0 V).
Fully recharge the battery and try again.
Paper jam: the paper is not inserted correctly.
Out of print paper: Insert paper.
Replace the batteries in the tester.
Analysis
The alternator output voltage is abnormally high.
Check that there are no connection problems. If
not, replace the alternator.
The voltage output of the alternator is
normal. No problems are detected.
The alternator does not provide enough current
for charging the electrical system and the battery.
Check the belts, and make sure the alternator is
running when the engine is running. If the belts
slip or are broken, replace the belts and retest.
Check the connection between the alternator
and the battery. If the connection is poor, clean
or replace the cable and retest. If the belts and
connection are in good condition, replace the
alternator.
C. Place a small length of paper
from the compartment and push the
transparent cover to close.
Analysis
EN