Electronic Control - TESY CN03 500W Instrucciones Para El Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
EN
Slide down the wall brace in order to detach it from
the back of the body.
Attach firmly the wall brace onto a wall through the
four screw holes.
Lift the panel heater up to almost vertical position
and insert the two lower protruding parts of the
braces into the two lower openings of the back
cover of the panel heater. Then lift the panel heater
and insert the two upper protruding parts of the
wall braces into the two upper openings of the back
cover of the heater. Finally, put the two screws back
to their places and tighten them in order to install
the panel heater firmly to the wall.
BATHROOM OPERATION
The panel heater must be installed in accordance
with the normal trade practices and in compliance
with the national legislation (EU electricity directives
and regulations concerning special installations and
places of operation including bathrooms, shower
cabins HD60364-7-701(IEC 60364-7-701:2006)).
4
Operation and Storage Manual
In case this panel heater is to be used in a bathroom
or other similar room, the following installation
requirements must be observed: the panel heater
is with IP24 protection (water drops protection).
Hence it can be installed in "Volume 2" (see the
diagram below) in order to avoid the risk of the
control board (power switch and thermo regulator)
being reached by a person who is in a shower or
a bathtub. The minimum distance between the
appliance and a water source should be not less
than 1 meter and it is compulsory the appliance
to be wall-mounted! If you do not feel sure about
the installation of this panel heater in a bathroom,
we recommend you to consult a professional
electrician.
Note: If the above-mentioned instructions cannot be
implemented, it is recommended to install the appliance
in "VOLUME 3".
In wet premises the power source must be installed
at a height of at least 25 cm above the floor
(bathrooms and kitchens).
The installation must be equipped with a safety
fuse, and the distance between the fuse contacts in
disconnected condition should be at least 3 mm.
OPERATION INSTRUCTIONS

ELECTRONIC CONTROL

Operation Modes
"Heating" mode LED /
Heater is operating
Time LED
Temperature LED
Starting "Heating" mode
When the panel heater is switched-off its digital display
should show the current room temperature and only
the "Temperature LED" should be illuminated. By single
pressing the ON/OFF button the appliance goes into
"Heating" mode. Then red diode light illuminates to
indicate that mode. For about 2 seconds the digital
display will show the adjusted temperature and for this
period of time the "Temperature" LED is off. If the room
temperature is lower than the set one, the heater will
switch on automatically.
"Delayed start" mode LED /
"Sleep" mode
Button "Timer" for
switching on "Delayed
start/stop" or "Sleep"
ON/OFF
mode
Button

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cn03 1000wCn03 1500wCn03 2000wCn03 2500wCn03 3000w

Tabla de contenido