ERROR CODE
E01
E02
E03
E08
E09
E10
E11
PAGE 10 OF 39
DESCRIPTION
The desk has an unknown
position and needs to be
initialized.
Overload in upward
direction has occurred.
Overload in downward
direction has occurred.
Indicate that software failed
to kick watchdog.
Collisions detected on the
LINBUS.
Power fail happened, or
power regulator adjusted
below 10%.
Change in number of
actuators since initialization.
ERROR CODES
CAUSES
Position error.
New desk leg added.
Obstruction.
Bad leg or motor cable.
Obstruction.
Bad leg or motor cable.
Program fault.
Key pressed on two or
more connected handset
simultaneously.
Multiple LINBUS devices
activated.
Power cord pulled during
driving.
Internal fault.
Only 1 battery for a 3- or
4-channel system.
Power fail, voltage on power
supply drops below a certain
limit, power removed.
Disconnection.
Desk Leg added.
RECOMMENDATIONS
Initialize the system.
Check all cable
connections, initialize the
system.
Troubleshoot components
by initializing one at a time.
Check all cable
connections, initialize the
system.
Troubleshoot components
by initializing one at a time.
Unplug cable for fifteen
seconds.
Initialize the system.
Replace control box.
Check if another desk panel
is connected and being
activated.
Unplug all but one desk
panel and test system.
Check cable is not caught,
and is allowed to freely
travel.
Use strain-relief loop built
into control box.
Use a second battery or
charge batteries.
Check motor cable
connections and Integrity.
Change motor cable or
desk leg.
Initialize the system.
0920 IH-8184