ERROR CODE
E29
E30
E35
E36
E41
E42
E47
E48
E53
PAGE 12 OF 39
ERROR CODES CONTINUED
DESCRIPTION
Channel 1 is not same type
as when initialized.
Channel 2 is not same type
as when initialized or not
same type as channel 1.
Channel 1 had to many
pulse errors.
Channel 2 had to many
pulse errors.
Overload up occurred on
channel 1.
Overload up occurred on
channel 2.
Overload down occurred on
channel 1.
Overload down occurred on
channel 2.
Anti-collision triggered on
channel 1.
CAUSES
Change in Desk Leg type.
Loose wire inside motor.
Change in desk leg type.
Loose wire inside motor.
Loose/faulty cable.
Hall sensor PCB.
Loose/faulty cable.
Hall sensor PCB.
Leg is overloaded.
Hit obstruction.
Reached end stop (before
initialization at upper
endstop occurs).
Leg is overloaded.
Hit obstruction.
Reached end stop (before
initialization at upper
endstop occurs).
Hit obstruction.
Hit obstruction.
Hit obstruction.
RECOMMENDATIONS
Check desk leg type.
Change desk leg.
Initialize the system.
Check desk leg type.
Change desk leg.
Initialize the system.
Check motor cable
connections and integrity.
Change desk leg.
Initialize the system.
Check motor cable
connections and integrity.
Change desk leg.
Initialize the system.
Remove obstruction.
Remove load.
Initialize if necessary.
Remove obstruction.
Remove load.
Initialize if necessary.
Remove obstruction.
Initialize if necessary.
Remove obstruction.
Initialize if necessary.
Remove obstruction.
Initialize if necessary.
0920 IH-8184