ERROR CODE
E12
E13
E15
E16
E17
E18
E23
E24
PAGE 11 OF 39
ERROR CODES CONTINUED
DESCRIPTION
One channel have position
different than others.
Short circuit detected during
operation.
System has reached its
power limitation.
Illegal keys pressed
(handled internally in DP1C).
LINBUS unit does not support
safety feature.
A special service tool is
required to change number
of channels to the system.
Channel 1 is detected
missing.
Channel 2 is detected
missing.
CAUSES
Too much back drive
occurred.
Squeezed motor cable.
Short in motor.
Power cord pulled during
driving.
Internal fault.
Many times will see this
alongside E10.
Power regulator has
adjusted speed down
on actuators without any
significant current draw,
usually caused by power
supply dropping.
Hitting multiple buttons
simultaneously.
DP1C/DPF1C does not have
up-to-date software.
Baselift only – Service tool
missing from baselift system
when initializing.
Disconnection.
Faulty motor cable.
Faulty motor in leg.
Disconnection.
Faulty motor cable.
Faulty motor in leg.
RECOMMENDATIONS
Move table to fully retracted
position.
Initialize system.
Check motor cable
connections.
Isolate and replace motor
cable.
Isolate and replace desk
leg.
Check mains cable is not
caught, and is allowed to
freely travel.
Use strain-relief loop built
into control box.
Check desk panel.
Try DP with more recent
software version (printed on
label).
Add service tool.
Check motor cable
connections and Integrity.
Change motor cable or
desk leg.
Initialize the system.
Check motor cable
connections and integrity.
Change motor cable or
desk leg.
Initialize the system.
0920 IH-8184