TROUBLESHOOTING

Symptoms
The mains indicator does not switch on
even after plugging the machine to the
mains
None of the indicators that indicate the
state of charge are switching on
The charger is properly connected but it
does not charge the battery
The fuse blows every time it is replaced
After charging for a whole day, the end of
charge indicator does not switch on.
WATTMATIC 100.140.170
Causes
No mains voltage
No mains voltage
Clamps in short circuit or polarity reversal.
Blown fuse
Bad clamp connections.
Wrong charge settings
Following intensive use, your device has
entered thermal protection mode.
Polarity reversal
Starting the vehicle
Wrong charge settings
Current overconsumption on the battery
The machine is charging a 6V battery in
12V mode
The battery is damaged
Translation of the original instructions
Remedies
Check that the power cord is plugged to a
230V 50/60Hz socket. Check the power
supply network.
Check that the power cord is plugged to a
230V 50/60Hz socket. Check the power
supply network.
Remove the clamps. Check that the fuses
have not melted and that the circuit breaker
is not tripped
Replace the fuse by a new one.
Clean the terminals and the clamps. Check
the state of the cables and clamps.
Check that the selected voltage matches
the battery voltage.
Wait 1/4h so the device can cool down.
Connect the + clamp to the battery's (+)
and the + clamp to the battery's (-).
Do not perform any starts when the charger
is connected.
Check that the selected voltage matches
the battery voltage.
Do not draw any of the battery's current
during the charge
Set the switch to 6V.
Change the battery.