1.4
FUNCTIONAL DIAGRAM
12
15
7
U
C
E
9
14
16
M
1
10
R
1.5
COMBUSTION
CHAMBER
The combustion chamber is of the
straight flow type and complies with
standard EN 303-3 appendix E.
The dimensions are shown in fig. 3.
L
mm
Estelle B4 INOX
405
Estelle B5 INOX
505
1.6
COMPATIBLE BURNERS
In general, the oil burner that is com-
patible with the boiler should use spray
of the semi solid type.
Section 1.6. 1 - 1.6.2 shows the mat-
ching table of the burners together
with the boilers have been tested with.
8
2
13
6
4
11
Volumen
dm
3
24,0
30,5
1.6. 1
"RIELLO" burners
Estelle B4 INOX
Estelle B5 INOX
1.6.2 "SIME" burners - NOx: Class 3
Estelle B4 INOX
Estelle B5 INOX
NOTE:
The best emission values are obtained with Danfoss 60°H nozzles. Use of Danfoss 60°H nozz-
les is recommended in the field to ensure continued dependable burner functioning.
KEY
1 Cast iron boiler
2 Water switch
3 Automatic air-vent
3
4 C.H. pump (not supplied)
6
5 D.H.W. tank pump
6 Non-return valve
7 D.H.W. safety valve 6 BAR
5
8 Magnesium anode
9 D.H.W. drain cock
10 Boiler drain cock
11 Burner (not supplied)
12 110 litre tank
13 Air vent valve
14 C.H.safety valve 3 BAR (not supplied)
15 D.H.W. tank expansion vessel
16 Hydrometer (not supplied)
270
Model
Nozzle
Tipo
RG1R
DELAVAN
0,75
R2000 G38R
DELAVAN
0,75
RG1R
DELAVAN
1,00
R2000 G46R
DELAVAN
0,85
Model
Nozzle
Tipo
BLUE MACK 1 LC
DANFOSS
BLUE MACK 2 LC
DANFOSS
(not supplied)
(not supplied)
L
Atomising
Pump pressure
ø
angle
60°W
60°W
60°W
60°W
Atomising
Pump pressure
ø
angle
0,65
60°S
0,75
60°H
Fig. 2
Fig. 3
bar
13,0
12,5
11,5
14,0
bar
12,0
12,0
35