MAINTENANCE OF THE BOIlER
To maintain your steam cleaner in good condition and to ensure constant performance,
we recommend that you clean the boiler every once or twice a year. depending on the
hardness of the water.
ClEANINg INSTRuCTIONS
ATTENTION: Before draining the boiler, please make sure that the machine is at room
temperature and that it is disconnected from the power source.
1. Take off the drainange cap at the bottom of the machine using a coin
2. Completely unscrew the boiler brass drainage nut, using a 20 mm hexagonal key (19).
3. After cleaning, twist close the drainage nut and replace the cap.
NOTE: if you see that the water that is coming out from the boiler is full of dirt/limestone,
we suggest that you repeat this operation more frequently, perhaps three to four times
per year.

TECHNICAl DESCRIPTION

120V ~ Power
Cold water tank capacity
Boiler capacity
Working pressure
Continuous steam system (CSS)
Steam Regulations
Safety valve
Hot water injection
Limestone Magnetic Filter
Certifications
09
1750W
3,1L
1,6L
6 bar
Yes
3
Yes
Yes
Yes
cETLus