Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: max.: 1 x 1,5 mm
EMC:
Interference emissions EN55011 Class B
Interference resistance EN 61000-6-2
Device safety (for the AC models):
Design to: EN61010 Part 1
Protection Class: 2
Application area: Soiling Level 2
Power supply:
Non-replaceable lithium battery
(lifetime approximately. 8 years at 20°C)
Input specifications, terminal assignment and adjustable time ranges (DC versions)
The time range is set via a control input (screw terminal 5).
Screw terminal
No. 1
Designation
INP A
Model
6.134.012.8x0
6.134.012.8x1
6.135.012.8x0
6.135.012.8x1
Table 2
Screw terminal 1:
no function
Screw terminal 2:
Timer Enable Input:
time measurement as long as
the input is active
NPN:
active for low level
Input resistance:
approximately 1 MOhm
Low level:
0 ... 0,7 V DC
High level:
3 ... 30 V DC
PNP:
active for high level
Input resistance:
approximately 100 kOhm
Low-level:
0 ... 0,7 V DC
High-level:
4 ... 30 V DC
Screw terminal 3:
Reset input:
active for negative edge contact
input / Open Collector NPN
(switching at 0 V DC)
Low level:
0 ... 0,7 V DC
High level:
3 ... 30 V DC
Min. pulse duration:
50 ms
Input resistance:
approximately 2,2 MOhm
2
2 x 0,75 mm
2
AWG 26-14
No. 2
No. 3 No. 4
INP B
Reset
Enable
NPN
PNP
NPN
PNP
Working temperature:
–10 ... +55 °C, relative humidity < 85%,
without condensation
Operating temperature:
–10 ... +60 °C
Storage temperature:
–20 .. +70°C
Altitude:
up to 2000 m
Backlighting:
must be powered by an external elecrical
source (24 V ±20%, 50 mA)
No. 5
Reset
Time range (Mode)
not active
=
99999 h 59 m
not active
=
9999 h 59 m 59 s
Screw terminal 4:
Electrical locking of the reset key
Contact input / Open Collector NPN
(switching at 0 V DC)
Low level:
High level:
Input resistance:
Input not active:
Reset key locked
Input active (contact with GND):
Reset key unlocked
Screw terminal 5:
Time range switching (Mode)
contact input / Open Collector NPN
(switching at 0 V DC)
Low level:
High level:
Input resistance:
Function:
No. 6 No. 7
GND
BL
contact with
GND
=
99999,99 h
contact with
GND
=
9999999,9 s
0 ... 0,7 V DC
3 ... 5 V DC
approximately. 2,2 MOhm
0 ... 0,7 V DC
3 ... 5 V DC
approximately. 2,2 MOhm
see table 2