Remark
If the time range is changed during operation,
the device must be reset, otherwise the
counting value will not be reproducible.
Screw terminal 6:
Common GND connection for all inputs
Input specification, terminal assignment and adjustable time ranges (AC versions)
The time range is set via a control input (screw terminal 5).
Screw terminal
designation
Model
6.134.012.8x3
6.135.012.8x3
Table 3
Screw terminal 1:
Timer Enable Input:
Optocoupler input
Low level:
High level:
Input resistance:
Screw terminal 2:
Common AC/DC, common connection for the optocou-
pler inputs (screw terminals 1 and 3)
Screw terminal 3:
Reset input:
Optocoupler input:
Min. pulse duration:
Max. frequency:
Low level:
High level:
Input resistance:
Screw terminal 4:
Electrical locking of the reset key
Contact input / Open Collector NPN
(switching at 0 V DC)
Low level:
High level:
Input resistance:
Input not active:
Input in contact with GND:
Reset key unlocked
Screw terminal 5:
Time range switching (Mode)
8
No. 1
No. 2
No. 3
INP A
Common
INP B
AC/DC
AC/DC
AC/DC
time measurement as long as
the level at this input is high.
10 ... 260 V AC/DC
galvanic isolation, active for
High signal
0 ... 2 V AC/V DC
10 ... 260 V AC/DC
approximately 160 kOhm
active for high level.
10 ... 260 V AC/DC galvanic
isolation, active for high signal
16 ms
approximately 30 Hz
0 ... 2 V AC/V DC
10 ... 260 V AC/DC
approximately 160 kOhm
0 ... 0,7 V DC
3 ... 5 V DC
approximately 2,2 MOhm
Reset key locked
Screw terminal 7:
(–) external power supply for the backlight option
Screw terminal 8:
(+) external power supply for the backlight option
(24 V DC ±20 %, 50 mA)
No. 4
No. 5
Reset
Time range (Mode)
Enable
not active
=
99999 h 59 m
not active
=
9999 h59m59s
Contact input / Open Collector NPN
(switching at 0 V DC)
Low level:
High level:
Input resistance:
Function:
Remark:
If the time range is changed during operation, the
device must be reset, otherwise the counting
value will not be reproducible.
Screw terminal 6:
Common GND connection for screw terminal 4
(reset key locking input) and screw terminal 5
(time range switching ).
Screw terminal 7:
(–) external power supply for the backlight option
Screw terminal 8:
(+) external power supply for the backlight option
(24 V DC ±20 %, 50 mA)

Scope of delivery:

Timer
Clamp
Front frame for screw mounting,
Panel cut-out 50 x 25 mm
Front frame for clamp mounting,
Panel cut-out 50 x 25 mm
Seal, Operating instructions
Note:
This product includes a lithium battery. Do
not open it by force, do not throw it in the
fire. Avoid temperatures below –20 °C and
above 70 °C!
No. 6 No. 7 No. 8
GND
contact with
GND
=
99999,99 h
contact with
GND
=
9999999,9 s
0 ... 0,7 V DC
3 ... 5 V DC
approximately 2,2 MOhm
see table 3
BL
BL
+