Operating instructions and warnings
Power supply input 230 V ~ +/- 10% 50Hz
1-2 230V ~
Flashing light output 230 V ~ max 40W
3-4
LAMP
Free contact max. capacity 5A : this contact can be used to control an open gate war-
5-6
ning light (P27=0) or a courtesy lamp (P27≠0)
LC/SCA
M1
Motor 1 output max 500W (7 opens, 8 common, 9 closes)
7-8-9
Motor 2 output max 500W (10 opens, 11 common, 12 closes)
10-11-12
M2
Electric lock output 12 V
13-14
ELETTR
15-16
+24 V ~ power supply output for auxiliary circuits and uncontrolled safety devices To
be used as power supply for any auxiliary devices, photocell receivers (in all cases), and
+24VAUX
of safety devices when you don't want to test these latter before each gate operation.
+24 V ~ power supply output for controlled safety devices. To be used as power supply
15-17
for photocell transmitters (in all cases) and of safety devices when testing these latter
+24VSIC
before each gate operation.
not used
18
input end of stroke operetor 2 while closing. If unused, short circuit to terminal n°23
19
FCC2
input end of stroke operetor 2 while opening. If unused, short circuit to terminal n°23
20
FCA2
21
input end of stroke operetor 1 while closing. If unused, short circuit to terminal n°23
FCC1
input end of stroke operetor 1 while opening. If unused, short circuit to terminal n°23
22
FCA1
Common inputs
23
COM
N.C. external safety device input of operator 2. In case of activation it reverses the
24
SIC2
movement (P18=0) or it stops (P18=1). If unused, short circuit to terminal n°28
N.C. external safety device input of operator 1. In case of activation it reverses the
25
movement (P18=0) or it stops (P18=1). If unused, short circuit to terminal n°28
SIC1
N.C. Photocell n. 2 input (external side). In case of activation it reverses the movement
26
only while closing (P26=0). If unused, short circuit to terminal n°28
FOTO2
N.C. Photocell n. 1 input (internal side). In case of activation it stops the movement
27
and reverses it once the obstacle has been removed. If P26=0 it is not considered, if
P026=1 it stops the movement and reverses it once the obstacle has been removed. If
FOTO1
unused, short circuit to terminal n°28
Common inputs
28
COM
N.C. stop input. If activated, it stops the movement during any operation. If unused,
29
short circuit to terminal n°32
STOP
N.O. pedestrian opening button input. If activated, it opens partially the gate
30
PED
N.O. open input. If activated, it opens or closes the gate. It can work in "reversal"
31
mode (P25=0) or "step-by-step" mode (P25=1)
START
Common inputs
32
18
COM
Aerial signal input
33
Aerial ground input
34
Connector input for eventual encoder of operator 2
J9
Connector input for eventual encoder of operator 1
J11
J8
Encoder selection Jumper:
A
B
•A position = operators with encoder (remind to set P034=0)
J10
A
•B position = operators without encoder (remind to set P034=1)
B
Table 1 Terminal board connection
15VA