CHECK CONNECTIONS FOR LEAKS
• Move HANDLE (1) into "off" position.
• Turn on water supplies and check connections for leaks.
• Operate HANDLE (2) up and down, left and right to flush
water lines thoroughly.
• Operate HAND SPRAY and check connections for leaks.
6
SERVICE
If Faucet Drips, Proceed As Follows:
• Turn VALVE to OFF position.
• Operate HANDLE several times from OFF to ON position. Do not apply excessive force.
Reduced Flow:
• Clean out spray head screen.
• Clean out cartridge.
Clogged CARTRIDGE outlets or inlets may
cause reduced flow.
To clean, first turn off water supply then:
• Loosen HANDLE SCREW (1) and remove
HANDLE (2).
• Unthread ESCUTCHEON CAP (3) and
ADAPTER (8). Unthread three
MOUNTING SCREWS (4).
• Lift CARTRIDGE (5) off MANIFOLD (6) and
remove CARTRIDGE SEALS (7).
• Clean MANIFOLD (6), CARTRIDGE (5)
ports and SEALS (7).
• Place SEALS (7) into CARTRIDGE
PORTS (5a).
• Place CARTRIDGE (5) onto
MANIFOLD (6) tighten ADAPTER (8)
and tighten MOUNTING SCREWS (5)
alternately.
• Replace ESCUTCHEON CAP (4),
HANDLE (2), tighten HANDLE
SCREW (1).
7

CARE INSTRUCTIONS:

DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CHECK CONNECTIONS